The Keurig B200 is a commercial-grade single-serve coffee brewer designed for office and light commercial use. This service manual covers technical specifications, maintenance procedures, troubleshooting, and repair instructions for qualified service technicians. The B200 features programmable settings, large water reservoir, multiple cup sizes, and compatibility with K-Cup pods.
Key technical details and operating parameters for the Keurig B200 brewer.
| Specification | Details |
|---|---|
| Power Requirements | 120V AC, 60Hz, 1470W |
| Water Reservoir Capacity | 90 oz (2.66L) |
| Brew Sizes | 4 oz, 6 oz, 8 oz, 10 oz |
| Dimensions | 13.2" H x 10.5" W x 14.5" D |
| Weight | 12.5 lbs (5.7 kg) |
| Operating Temperature | 40°F - 95°F (4°C - 35°C) |
| Brew Time | Approximately 60 seconds |
| Pump Pressure | Up to 65 PSI |
| Heater Type | 1400W stainless steel |
| Certifications | UL, NSF, Energy Star |
Critical safety information for service technicians.
WARNING! High voltage and hot surfaces present. Failure to follow safety procedures may result in serious injury or equipment damage.
Major components and their functions.
| Component | Function |
|---|---|
| Main Control Board | Processes user input and controls brewing cycle |
| Heater Assembly | Heats water to brewing temperature |
| Water Pump | Circulates water through the system |
| Needle Assembly | Punctures K-Cup and injects hot water |
| Drip Tray | Collects spills and overflow |
| Water Reservoir | Stores cold water supply |
| Thermal Fuse | Safety device to prevent overheating |
| Temperature Sensor | Monitors water temperature |
Step-by-step disassembly instructions.
CAUTION! Label all wiring connections for proper reassembly.
Recommended maintenance intervals.
Common issues and solutions.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Brewer won't power on | Power supply, thermal fuse | Check power cord, test thermal fuse, verify outlet |
| No water flow | Clogged needles, pump failure | Clean needles, test pump, check water lines |
| Water not heating | Heater failure, thermostat | Test heater resistance, check thermostat |
| Error codes displayed | Sensor faults, system errors | Refer to error code section, reset brewer |
| Leaking water | Seal failure, cracked reservoir | Inspect seals, replace damaged components |
Diagnostic error codes and resolutions.
| Error Code | Description | Resolution |
|---|---|---|
| E-01 | Water temperature fault | Check heater, temperature sensor |
| E-02 | Brew timeout | Clean needles, check water flow |
| E-03 | Over-temperature | Reset thermal fuse, check thermostat |
| E-04 | Water sensor fault | Check water level sensor |
| E-05 | Pump fault | Test pump motor, check wiring |
Service mode access and calibration procedures.
NOTE: Record original settings before making changes.
Common replacement parts and part numbers.
| Part Description | Part Number |
|---|---|
| Heater Assembly | B200-HEAT-001 |
| Water Pump | B200-PUMP-002 |
| Needle Assembly | B200-NEED-003 |
| Main Control Board | B200-CONT-004 |
| Thermal Fuse | B200-FUSE-005 |
| Drip Tray Assembly | B200-TRAY-006 |
| Water Reservoir | B200-RESV-007 |
| Temperature Sensor | B200-TEMP-008 |
Electrical schematics and connector identification.
Refer to separate wiring diagram supplement. Diagrams show:
WARNING! Always verify power is disconnected before testing circuits.
Proper reassembly sequence and testing.
VERIFICATION: Ensure all components function properly before returning to service.